NOx and Ultra Low NOx emissions

NOx are oxides of nitrogen formed during the combustion of fossil fuels. They also arise during combustion by the direct combination of atmospheric nitrogen and oxygen at high temperature. The main component of NOx is nitric oxide (NO), with a smaller proportion of nitrogen dioxide (NO₂). The most commonly used unit of measurement of NOx […]

Monolinks

Monolinks are small manifolds which enable connections to be made simply and effectively to fan coil and air handling units. They each include a full-bore bypass which significantly reduces commissioning time.  Each Monolink module is supplied as a single assembly and is connected to its terminal unit by just four unions, making it easy to […]

Mechanical Ventilation

Mechanical ventilation systems use fans to supply fresh or tempered air to a space, and can also extract stale air from it. They can be designed as a centralised facility to supply ducted air throughout a building, or as discrete units selected to ventilate single rooms at a time. (Natural ventilation methods, on the other hand, […]

Manifold

A manifold is a pipe or chamber that branches into several openings. It is used as a distribution hub and can be selected with integral isolators at each branch.  Manifolds reduce the number of connections to be made on site and thus have excellent time-saving potential. Factory-made assemblies often include fittings such as air vents, […]

M-Bus Wiring

M-Bus (short for Meter-Bus), is a European standard (EN 13757-2 for physical and link layer, EN 13757-3 for application layer) developed for the remote reading of utility meters. M-Bus is designed to facilitate the monitoring and measurement of energy consumption to assist with energy conservation. The M-Bus interface is designed to use two wires, though there […]

Mechanical Ventilation with Heat Recovery (MVHR)

Mechanical ventilation systems are those which incorporate a fan or similar device to assist air movement.  An important subset of this main category is mechanical ventilation with heat recovery (MVHR).  These systems extract heat from exhaust air and transfer it to incoming fresh air, greatly reducing the heat energy which would otherwise be lost from […]

Local Control (AirMaster)

For classrooms, we recommend using a local control panel (Airlinq Viva for single units and Airlinq Orbit for multiples) with an integrated CO₂ sensor installed within the master unit.  For rooms of intermittent occupancy, we recommend using a local control panel (Airlinq Viva for single units and Airlinq Orbit for multiples) with an integrated or […]

LoadTracker XRGI 9G CHP

High efficiency combined heat and power (CHP) unit with maximum rating of 9 kW(e) / 19 kW(th). Can modulate down to 50% load, = 4.5kW(e) / 12 kW(th).  Offered with 4 main components: Power unit, comprising gas-fired engine and generator.  Heat distributor assembly, for ease of interfacing with building heating systems.  Control panel, for matching […]

LoadTracker XRGI 6G CHP

High efficiency combined heat and power (CHP) unit with maximum rating of 6kW(e) / 12 kW(th). Can modulate down to 50% load, = 3 kW(e) / 8 kW(th).  Offered with 4 main components: Power unit, comprising gas-fired engine and generator.  Heat distributor assembly, for ease of interfacing with building heating systems.  Control panel, for matching […]

LoadTracker XRGI 20G CHP

High efficiency combined heat and power (CHP) unit with maximum rating of 20kW(e) / 40 kW(th). Can modulate down to 50% load, = 10kW(e) / 26 kW(th).  Offered with 4 main components: Power unit, comprising gas-fired engine and generator.  Heat distributor assembly, for ease of interfacing with building heating systems.  Control panel, for matching of […]

Search

To search for documents, please visit Downloads and use the search function / filters on that page.

    If you are unsure or would like to speak to us directly, please contact +44 (0) 1483 771910

    Submit Your Enquiry

    Provide us with the relevant information in the form and our team will reach out to you